Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Bioanal Chem ; 411(17): 3919-3928, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31104085

RESUMO

In this study, a special interest was focused on the stability of diazepam and nordiazepam in aqueous samples at acidic and neutral pH. The aim of the study was to isolate and illustrate one of the many possible sources of error that can be encountered when developing and validating analytical methods. This can be of particular importance when developing multi-analyte methods where there is limited time to scrutinize the behavior of each analyte. A method was developed for the analysis of the benzodiazepines diazepam and nordiazepam in treated wastewater. The samples were extracted by solid phase extraction, using SPEC C18AR cartridges, and analyzed by the use of liquid chromatography, with a C18 stationary phase, coupled to tandem mass spectrometry. Environmental water samples are often acidified during storage to reduce the microbial degradation of the target compounds and to preserve the sample. In some cases, the samples are acidified before extraction. In this study, it was found that a chemical equilibrium between nordiazepam and a transformation product could cause inaccurately high extraction recovery values when the samples were stored at low sample pH. The stability of nordiazepam was shown to be low at pH 3. Within 12 days, 20% of the initial concentration of nordiazepam was transformed. Interestingly, the transformed nordiazepam was shown to be regenerated and reformed to nordiazepam during sample handling. At a sample pH of 7, diazepam and nordiazepam were stable for 12 days. It was concluded that great care must be taken when acidifying water samples containing nordiazepam during storage or extraction. The storage and the extraction should be conducted at neutral pH if no internal standard is used to compensate for degradation and conversion of nordiazepam. The developed method was validated in treated wastewater and applied for the quantification of diazepam and nordiazepam in treated wastewater samples.


Assuntos
Ácidos/química , Cromatografia Líquida/métodos , Diazepam/química , Nordazepam/química , Espectrometria de Massas em Tandem/métodos , Poluentes Químicos da Água/análise , Concentração de Íons de Hidrogênio , Limite de Detecção , Extração em Fase Sólida/métodos
2.
J Chromatogr A ; 1269: 208-17, 2012 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-23089516

RESUMO

A LC-MS/MS method for the chiral separation of metoprolol and two of its main metabolites, α-hydroxymetoprolol (α-OH-Met) and deaminated metoprolol (COOH-Met), in environmental water samples has been developed. The target bases, metoprolol and α-OH-Met, as well as the acidic metabolite (COOH-Met) were extracted from water samples by a solid phase extraction method employing Oasis HLB cartridges. The extraction recoveries were ≥ 73% for all compounds in surface water. Four different types of chiral stationary phases were investigated for the separation of the eight stereoisomers of metoprolol and its metabolites, Chiralcel OD-H, Chirobiotic V, Chiral AGP and Chiral CBH. In the final method, the enantiomers of metoprolol and four stereoisomers of α-OH-Met were separated using Chiral CBH, the enantiomers of COOH-Met were separated employing Chiral AGP. The analytes were detected in SRM mode by triple quadrupole mass spectrometry. The method was applied for the chiral analysis of the analytes in treated wastewater samples from Uppsala, Sweden. The enantiomers and diastereoisomers of α-OH-Met were detected and analyzed in the samples. The concentrations of the three first eluting stereoisomers of α-OH-Met were between 54 and 61 pM. Interestingly, the last eluting stereoisomer was found to be present at a concentration of 151 pM at the same sampling occasion. This is, to the best of the authors' knowledge, the first time the stereoisomers of α-OH-Met have been detected in wastewater samples. The enantiomers of metoprolol were determined to be 1.77 and 1.86 nM in the same matrix. The enantiomers of COOH-Met were not detected above the method detection limit (42 pM) in treated wastewater samples. The developed LC-MS/MS methods were validated in wastewater samples.


Assuntos
Antagonistas Adrenérgicos beta/análise , Cromatografia Líquida/métodos , Metoprolol/análogos & derivados , Metoprolol/análise , Espectrometria de Massas em Tandem/métodos , Águas Residuárias/química , Poluentes Químicos da Água/análise , Desaminação , Extração em Fase Sólida , Estereoisomerismo
3.
J Chromatogr A ; 1227: 105-14, 2012 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-22265784

RESUMO

The isotope-labeled compounds fluoxetine-d5 and norfluoxetine-d5 were used to study matrix effects caused by co-eluting compounds originating from raw and treated wastewater samples, collected in Uppsala, Sweden. The matrix effects were investigated by the determination of matrix factors (MF) and by a post-column infusion method. The matrix factors were determined to be 38-47% and 71-86% for the enantiomers of norfluoxetine-d5 and fluoxetine-d5, respectively. The influence of matrix effects when quantifying the enantiomers of the active pharmaceutical ingredient and the metabolite in wastewater samples with LC-MS/MS is discussed and methods to overcome the problem are presented. The enantiomeric concentrations of fluoxetine and its human metabolite norfluoxetine, quantified by a one-point calibration method, were 12-52 pM (3.5-16 ng L⁻¹) in raw wastewater and 4-48 pM (1.2-15 ng L⁻¹) in treated wastewater. Furthermore, the calculated enantiomeric fractions (EF) of the substances were found to be between 0.68 and 0.71 in both matrices. Neither the EF values for fluoxetine nor those for norfluoxetine were significantly different in the raw wastewater compared to the treated wastewater. Interestingly, the concentration of (S)-fluoxetine was found to be higher than the concentration of (R)-fluoxetine in both raw and treated wastewater. These results are different from other results presented in the literature, which shows that the relative concentrations of the enantiomers of a chiral active pharmaceutical ingredient might be significantly different in wastewater samples from different treatment systems. We report, for the first time, the concentrations of the enantiomers of norfluoxetine in wastewater samples. The concentrations of (S)-norfluoxetine were found to be higher than the concentration of (R)-norfluoxetine in the raw as well as in the treated wastewater samples.


Assuntos
Cromatografia Líquida/métodos , Fluoxetina/análogos & derivados , Esgotos/química , Extração em Fase Sólida/métodos , Poluentes Químicos da Água/análise , Calibragem , Deutério , Fluoxetina/análise , Fluoxetina/isolamento & purificação , Reprodutibilidade dos Testes , Estereoisomerismo , Espectrometria de Massas em Tandem/métodos , Poluentes Químicos da Água/isolamento & purificação
4.
J Chromatogr A ; 1218(33): 5587-96, 2011 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-21752386

RESUMO

An enantioselective method for the determination of fluoxetine (a selective serotonin reuptake inhibitor) and its pharmacologically active metabolite norfluoxetine has been developed for raw and treated wastewater samples. The stable isotope-labeled fluoxetine and norfluoxetine were used in an extended way for extraction recovery calculations at trace level concentrations in wastewater. Wastewater samples were enriched by solid phase extraction (SPE) with Evolute CX-50 extraction cartridges. The obtained extraction recoveries ranged between 65 and 82% in raw and treated wastewater at a trace level concentration of 50 pM (15-16 ng L⁻¹). The target compounds were identified by the use of chiral liquid chromatography tandem mass spectrometry (LC-MS/MS) in selected reaction monitoring (SRM) mode. The enantiomers were successfully resolved on a chiral α1-acid glycoprotein column (chiral AGP) with acetonitrile and 10 mM ammonium acetate buffer at pH 4.4 (3/97, v/v) as the mobile phase. The effects of pH, amount of organic modifier and buffer concentration in the mobile phase were investigated on the enantiomeric resolution (R(s)) of the target compounds. Enantiomeric R(s)-values above 2.0 (1.03 RSD%, n=3) were achieved for the enantiomers of fluoxetine and norfluoxetine in all mobile phases investigated. The method was validated by assessing parameters such as cross-contamination and carryover during SPE and during LC analysis. Cross-talk effects were examined during the detection of the analytes in SRM mode. In addition, the isotopic purity of fluoxetine-d5 and norfluoxetine-d5 were assessed to exclude the possibility of self-contamination. The interassay precision of the chromatographic separation was excellent, with relative standard deviations (RSD) equal to or lower than 0.56 and 0.81% in raw and treated wastewaters, respectively. The method detection and quantification limits (respectively, MDL and MQL) were determined by the use of fluoxetine-d5 and norfluoxetine-d5. The MQL for the single enantiomers ranged from 12 to 14 pM (3.6-4.3 ng L⁻¹) in raw wastewater and from 3 to 4 pM (0.9-1 ng L⁻¹) in treated wastewater. The developed method has been employed for the quantification of (R)-fluoxetine, (S)-fluoxetine and the enantiomers of norfluoxetine in raw and treated wastewater samples to be presented in Part II of this study.


Assuntos
Antidepressivos/análise , Cromatografia Líquida/métodos , Fluoxetina/análogos & derivados , Fluoxetina/análise , Espectrometria de Massas em Tandem/métodos , Poluentes Químicos da Água/análise , Fluoxetina/metabolismo , Esgotos/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...